Gold Member Since 2016
Audited Supplier
Precision (Changzhou) Medical Instruments Co., Ltd.

Surgical Stapler, Disposable Circular Stapler, Circular Stapler manufacturer / supplier in China, offering Disposable Surgical Stapler for Esophagus with Ce, New Circular Stapler for Rectal Prolapse and Hemorrhoids, Surgical Stapler/Disposable Linear Stapler for Abdominal Surgery and so on.

(/ )

Supplier Homepage Product Disposable surgical stapler Others Disposable surgical stapler Disposable Surgical Stapler for Esophagus with Ce

Disposable Surgical Stapler for Esophagus with Ce

FOB Price: US $72-88 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $72-88/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 50000PCS/Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: PYGX-17/19/21/23/26/29/32/33/35
  • Application: Abdominal, Esophagus,Gastrointestinal
  • Feature: Disposable
  • Group: Adult
  • Medical Devices Reg./Record No.: Cfda2014-2080083
  • Transport Package: 1PCS in Sterlized Box, Packed in Carton
  • Origin: Changzhou Jiangsu China
  • Type: Gastrointestinal Surgical Stapler
  • Material: Titanium
  • Certification: CE, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Trademark: REAL
  • Specification: ABS, TA2 stainless steel
  • HS Code: 90189090
Product Description
Disposable circular stapler

     CHARACTERS
     32 meadle design to reduce bleeding
     Relieve ache after operation and speedup the period of recovery
     Extralarge camidgevolume for more tissue 
A. Usage of Disposable Circular Stapler
Open the package to take out the stapler and remove the cartridge cover.
2. Put the stapler into the organ to be stapled until the anvil is exposed entirely (Figure 2).
3. Turn the adjusting handle at the rear of the instrument counterclockwise to open the space between the anvil and the stapling & cutting assembly to admit two broken ends of the stapling site. Tighten up the purse at one end of the stapling & cutting assembly and tie up the purse string to the puncturing shaft with a proper force, making sure that all the tissue falls into the range of the stapling & cutting assembly. Next, tighten up the purse at one end of the locating shaft and tie up the purse string to the locating shaft with a proper force, making sure that all the tissue falls into the range of the anvil .
4. If the instrument needs to pass through from the organ which is closed at one side, separate the anvil from the instrument first, and then turn the adjusting handle clockwise to pull back the puncturing shaft to the stapling assembly, thus avoiding tissue damage when it is inserted into the organ .
5. Put the anvil into the organ for purse ligation. It's better to apply some lubricant such as K-Y glue to the anvil to make the surgical operation convenient
6. Insert the stapler into the organ, with its stapling & cutting assembly close to the site to be stapled; turn the adjusting handle counterclockwise to pull out the puncturing shaft slowly to fully pierce the tissue. If the double stapling technique is necessary, please be sure that the puncturing shaft pierces from the center of the suture so as to avoid the excessive tissue accumulating around the puncturing shaft  
7. When the puncturing shaft is totally exposed, the locating shaft on the anvil can be encased in the puncturing shaft. When a clear "click" sounds, it means that the connection is completed
8. Turn the adjusting handle at the tail clockwise to draw the tissue at both ends together (Figure 8) until the indicator gets to the green zone (the force shall not be too great to crush the tissue).
Note: The instrument is equipped with safety design, so that the security button cannot be opened when the indicator is not within the green zone. Be sure not to open it violently. If the indictor still remains outside the green zone when the instrument is totally tightened, it means that the tissue in the instrument is too much, and the instrument shall be opened for separation again.
9. The instrument can be fired when the security button is opened and the handle is held. When a clear "click" sounds and an obvious feeling of penetration is gotten, it means that the firing has been completed. 
10. Turn the adjusting handle counterclockwise to draw out the stapler slowly.
11. If there are sites which are not fully stapled in the operation, please suture them.
B.NOTE
1. The instrument can only be operated by doctors who have received adequate training and get familiar with operation skills.
2. Be sure to check the sutured tissue for bleeding when the instrument is removed; if there is blood oozing, proper methods shall be adopted to stanch bleeding.
3. Please check the package carefully before use; it is prohibited to use if the package is damaged.
4. The product has been sterilized by ethylene oxide, and its validity period of sterilization is three years, so that please check whether the product is within the validity period. If the validity period expires, the product shall not be used.
5. The product is for single use only, so that it cannot be reused even with sterilization again.
6. Be sure to choose suitable specification of assembly according to the tissue thickness; too thick or too thin tissues many cause bad nail forming.

Disposable Surgical Stapler for Esophagus with Ce
1.Anvil  2.stapling and cutting assembly 3.Elbow 4.Fixed handle 5.free handle 6.adjusting nut 7.suturing stapler

Disposable Surgical Stapler for Esophagus with CeDisposable Surgical Stapler for Esophagus with Ce

 
ModelHeight of Nail(mm)Number of Titanium NailCutting Diameter(mm)Outside Diameter(mm)
PYGC-324.2322432
PYGC-344.2322634
PYGC-364.2322836